Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
1.
J Clin Lab Anal ; 37(7): e24889, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: covidwho-20235392

RESUMEN

BACKGROUND: Polymerase chain reaction (PCR) has been widely used for many pathogen detection. However, PCR technology still suffers from long detection time and insufficient sensitivity. Recombinase-aided amplification (RAA) is a powerful nucleic acid detection tool with high sensitivity and amplification efficiency, but its complex probes and inability of multiplex detection hinder the further application of this technology. METHODS: In this study, we developed and validated the multiplex reverse transcription recombinase-aided PCR (multiplex RT-RAP) assay for human adenovirus 3 (HADV3), human adenovirus 7 (HADV7), and human respiratory syncytial virus (HRSV) within 1 h with Human RNaseP protein as a reference gene to monitor the whole process. RESULTS: Using recombinant plasmids, the sensitivity of multiplex RT-RAP for the detection of HADV3, HADV7, and HRSV was 18, 3, and 18 copies per reaction, respectively. The multiplex RT-RAP showed no cross-reactivity with other respiratory viruses, demonstrating its good specificity. A total of 252 clinical specimens were tested by multiplex RT-RAP and the results were found to be consistent with those of corresponding RT-qPCR assays. After testing serial dilutions of selected positive specimens, the detection sensitivity of multiplex RT-RAP was two to eightfold higher than that of corresponding RT-qPCR. CONCLUSION: We conclude the multiplex RT-RAP is a robust, rapid, highly sensitive, and specific assay with the potential to be used in the screening of clinical samples with low viral load.


Asunto(s)
Adenovirus Humanos , Virus Sincitial Respiratorio Humano , Humanos , Virus Sincitial Respiratorio Humano/genética , Adenovirus Humanos/genética , Transcripción Reversa , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Reacción en Cadena de la Polimerasa Multiplex , Sensibilidad y Especificidad
2.
J Infect Chemother ; 29(8): 778-782, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: covidwho-2325110

RESUMEN

BACKGROUND: For patients with coronavirus disease 2019 (COVID-19) requiring hospitalization, extending isolation is warranted. As a cautious protocol, ending isolation based on polymerase chain reaction cycle threshold (Ct) value was introduced for patients requiring therapy for >20 days after symptom onset. METHOD: We compared a Ct-based strategy using Smart Gene® between March 2022 and January 2023 with a preceding control period (March 2021 to February 2022) when two consecutive negative reverse transcription-polymerase chain reaction tests using FilmArray® were required for ending isolation. Ct was evaluated on day 21, and ending isolation was permitted in patients with Ct ≥ 38. Although patients with Ct 35-37 were transferred to a non-COVID-19 ward, isolation was continued. RESULTS: The duration of stay on a COVID-19 ward in the Ct group was 9.7 days shorter than that in controls. The cumulative number of tests was 3.7 in controls and 1.2 in the Ct group. There was no nosocomial transmission after ending isolation in either group. The number of days from symptom onset to testing was 20.7 ± 2.1 in Ct group, and five patients had Ct < 35, nine Ct 35-37, and 71 Ct ≥ 38. No patients were moderately or severely immunocompromised. Steroid use was an independent risk factor for prolonged low Ct (odds ratio 9.40, 95% confidence interval 2.31-38.15, p = 0.002) CONCLUSIONS: The efficacy of ending isolation based on Ct values could improve bed utilization without the risk of transmission among patients with COVID-19 requiring therapy for >20 days after symptom onset.


Asunto(s)
COVID-19 , Humanos , SARS-CoV-2/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Transcripción Reversa , Hospitales , Reacción en Cadena de la Polimerasa , Prueba de COVID-19
3.
Appl Microbiol Biotechnol ; 107(12): 3983-3996, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: covidwho-2314427

RESUMEN

The outbreak of coronavirus disease 2019 (COVID-19) in 2019 has severely damaged the world's economy and public health and made people pay more attention to respiratory infectious diseases. However, traditional quantitative real-time polymerase chain reaction (qRT-PCR) nucleic acid detection kits require RNA extraction, reverse transcription, and amplification, as well as the support of large-scale equipment to enrich and purify nucleic acids and precise temperature control. Therefore, novel, fast, convenient, sensitive and specific detection methods are urgently being developed and moving to proof of concept test. In this study, we developed a new nucleic acid detection system, referred to as 4 Thermostatic steps (4TS), which innovatively allows all the detection processes to be completed in a constant temperature device, which performs extraction, amplification, cutting of targets, and detection within 40 min. The assay can specifically and sensitively detect five respiratory pathogens, namely SARS-CoV-2, Mycoplasma felis (MF), Chlamydia felis (CF), Feline calicivirus (FCV), and Feline herpes virus (FHV). In addition, a cost-effective and practical small-scale reaction device was designed and developed to maintain stable reaction conditions. The results of the detection of the five viruses show that the sensitivity of the system is greater than 94%, and specificity is 100%. The 4TS system does not require complex equipment, which makes it convenient and fast to operate, and allows immediate testing for suspected infectious agents at home or in small clinics. Therefore, the assay system has diagnostic value and significant potential for further reducing the cost of early screening of infectious diseases and expanding its application. KEY POINTS: • The 4TS system enables the accurate and specific detection of nucleic acid of pathogens at 37 °C in four simple steps, and the whole process only takes 40 min. •A simple alkali solution can be used to extract nucleic acid. • A small portable device simple to operate is developed for home diagnosis and detection of respiratory pathogens.


Asunto(s)
COVID-19 , Humanos , Animales , Gatos , COVID-19/diagnóstico , SARS-CoV-2/genética , Sistemas CRISPR-Cas , Reacción en Cadena en Tiempo Real de la Polimerasa , Transcripción Reversa , Sensibilidad y Especificidad , Técnicas de Amplificación de Ácido Nucleico/métodos
4.
J Microbiol Methods ; 209: 106738, 2023 06.
Artículo en Inglés | MEDLINE | ID: covidwho-2318087

RESUMEN

Neonatal calf diarrhea (NCD) is frequently associated with single or mixed viral, bacterial and/or protozoal infections. Consequently, laboratory diagnostic of NCD usually requires specific tests for each potential agent; a time-consuming, laborious and expensive process. Herein, we describe an end-point multiplex PCR/reverse transcription-PCR (RT-PCR) for detection of five major NCD agents: bovine rotavirus (BRV), bovine coronavirus (BCoV), Escherichia coli K99 (E. coli K99), Salmonella enterica (S. enterica) and Cryptosporidium parvum (C. parvum). Initially, we selected and/or designed high-coverage primers. Subsequently, we optimized multiplex PCR/RT-PCR conditions. Next, we evaluated the analytical sensitivity of the assay and assessed the performance of the reaction by testing 95 samples of diarrheic calf feces. The analytical specificity was evaluated against bovine viral diarrhea virus (BVDV), E. coli heat-stable enterotoxin (STa) and Eimeria spp. The detection limit of our assay was about 10 infectious units of BRV, 10-2 dilution of a BCoV positive sample pool, about 5 × 10-4 CFU for S. enterica, 5 × 10-6 CFU for E. coli K99 and 50 oocysts for C. parvum. No non-specific amplification of other bovine diarrhea agents was detected. Out of 95 samples analyzed, 50 were positive for at least one target, being 35 single and 15 mixed infections. BRV was the most frequent agent detected in single infections (16/35), followed by Cryptosporidium spp. (11/35), which was the most frequent in mixed infections (11/15). Positive and negative multiplex results were confirmed in individual reactions. In conclusion, we described an end-point multiplex PCR/RT-PCR for faster and easier NCD diagnosis, which may be useful for routine diagnosis and surveillance studies.


Asunto(s)
Coinfección , Criptosporidiosis , Cryptosporidium parvum , Cryptosporidium , Enfermedades no Transmisibles , Recién Nacido , Humanos , Reacción en Cadena de la Polimerasa Multiplex , Escherichia coli , Criptosporidiosis/diagnóstico , Transcripción Reversa , Diarrea/diagnóstico , Diarrea/veterinaria , Cryptosporidium parvum/genética
5.
Viruses ; 15(3)2023 02 25.
Artículo en Inglés | MEDLINE | ID: covidwho-2288559

RESUMEN

SARS-CoV-2 sequences can be reverse-transcribed and integrated into the genomes of virus-infected cells by a LINE1-mediated retrotransposition mechanism. Whole-genome sequencing (WGS) methods detected retrotransposed SARS-CoV-2 subgenomic sequences in virus-infected cells overexpressing LINE1, while an enrichment method (TagMap) identified retrotranspositions in cells that did not overexpress LINE1. LINE1 overexpression increased retrotranspositions about 1000-fold as compared to non-overexpressing cells. Nanopore WGS can directly recover retrotransposed viral and flanking host sequences, but its sensitivity depends on the depth of sequencing (a typical 20-fold sequencing depth would only examine 10 diploid cell equivalents). In contrast, TagMap enriches the host-virus junctions and can interrogate up to 20,000 cells and is able to detect rare viral retrotranspositions in LINE1 non-overexpressing cells. Although Nanopore WGS is 10-20-fold more sensitive per tested cell, TagMap can interrogate 1000-2000-fold more cells and, therefore, can identify infrequent retrotranspositions. When comparing SARS-CoV-2 infection and viral nucleocapsid mRNA transfection by TagMap, retrotransposed SARS-CoV-2 sequences were only detected in infected but not in transfected cells. Retrotransposition in virus-infected cells, in contrast to transfected cells, may be facilitated because virus infection, in contrast to viral RNA transfection, results in significantly higher viral RNA levels and stimulates LINE1 expression by causing cellular stress.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , SARS-CoV-2/metabolismo , Transcripción Reversa , ARN Mensajero/genética , ARN Viral/genética , ARN Viral/metabolismo , Genómica
6.
Anal Chim Acta ; 1255: 341146, 2023 May 15.
Artículo en Inglés | MEDLINE | ID: covidwho-2288467

RESUMEN

The spreading of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) across the world has impacted people's health and lives worldwide in recent years. Rapid and accurate diagnosis is crucial for curbing the pandemic of coronavirus disease 2019 (COVID-19). Reverse transcription loop-mediated isothermal amplification (RT-LAMP) has great potential for SARS-CoV-2 detection but fails to completely replace conventional PCR due to the high false-positive rate (FPR). We proposed a triple-target RT-LAMP method for dual-signal, sensitive, and simultaneous detection of conserved genes of SARS-CoV-2. Multiple LAMP primer sets were designed for N, E, and M genes and their amplification efficacy were screened. Then, using artificial plasmids and RNA, the optimal primer set for each gene was examined on specificity, sensitivity, and detection range. The RT-LAMP initiated by these primer sets exhibited better specificity and sensitivity than that of RT-qPCR, and the triple-target RT-LAMP could determine different variants of SARS-CoV-2. By testing 78 artificial RNA samples, the total FPR of triple-target RT-LAMP was eliminated compared with that of mono-target RT-LAMP. The triple-target RT-LAMP method precisely identified throat swab specimens through colorimetry and fluorescent signals within 60 min, and the limit of detection (LOD) was as low as 187 copies/reaction. In the future, the triple-target RT-LAMP can be applied to in-field and on-site diagnosis of symptomatic and asymptomatic virus carriers.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Transcripción Reversa , Técnicas de Laboratorio Clínico/métodos , Prueba de COVID-19 , Sensibilidad y Especificidad , Técnicas de Amplificación de Ácido Nucleico/métodos , ARN Viral/genética , ARN Viral/análisis
7.
J Med Virol ; 95(2): e28444, 2023 02.
Artículo en Inglés | MEDLINE | ID: covidwho-2263443

RESUMEN

Coronavirus disease 2019 (COVID-19) is a highly infectious disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-COV-2). Though many methods have been used for detecting SARS-COV-2, development of an ultrafast and highly sensitive detection strategy to screen and/or diagnose suspected cases in the population, especially early-stage patients with low viral load, is significant for the prevention and treatment of COVID-19. In this study, a novel restriction endonuclease-mediated reverse transcription multiple cross displacement amplification (MCDA) combined with real-time fluorescence analysis (rRT-MCDA) was successfully established and performed to diagnose COVID-19 infection (COVID-19 rRT-MCDA). Two sets of specific SARS-COV-2 rRT-MCDA primers targeting opening reading frame 1a/b (ORF1ab) and nucleoprotein (NP) genes were designed and modified according to the reaction mechanism. The SARS-COV-2 rRT-MCDA test was optimized and evaluated using various pathogens and clinical samples. The optimal reaction condition of SARS-COV-2 rRT-MCDA assay was 65°C for 36 min. The SARS-COV-2 rRT-MCDA limit of detection (LoD) was 6.8 copies per reaction. Meanwhile, the specificity of SARS-COV-2 rRT-MCDA assay was 100%, and there was no cross-reaction with nucleic acids of other pathogens. In addition, the whole detection process of SARS-COV-2 rRT-MCDA, containing the RNA template processing (15 min) and real-time amplification (36 min), can be accomplished within 1 h. The SARS-COV-2 rRT-MCDA test established in the current report is a novel, ultrafast, ultrasensitive, and highly specific detection method, which can be performed as a valuable screening and/or diagnostic tool for COVID-19 in clinical application.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Transcripción Reversa , Prueba de COVID-19 , Enzimas de Restricción del ADN/genética , Técnicas de Diagnóstico Molecular/métodos , Sensibilidad y Especificidad , Técnicas de Amplificación de Ácido Nucleico/métodos , ARN Viral/genética
8.
Food Environ Virol ; 15(1): 71-81, 2023 03.
Artículo en Inglés | MEDLINE | ID: covidwho-2245002

RESUMEN

Faecal shedding of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and its subsequent detection in wastewater turned the spotlight onto wastewater-based epidemiology (WBE) for monitoring the coronavirus-disease 2019 (COVID-19) pandemic. WBE for SARS-CoV-2 has been deployed in 70 countries, providing insights into disease prevalence, forecasting and the spatiotemporal tracking and emergence of SARS-CoV-2 variants. Wastewater, however, is a complex sample matrix containing numerous reverse transcription quantitative PCR (RT-qPCR) inhibitors whose concentration and diversity are influenced by factors including population size, surrounding industry and agriculture and climate. Such differences in the RT-qPCR inhibitor profile are likely to impact the quality of data produced by WBE and potentially produce erroneous results.To help determine the possible impact of RT-qPCR assay on data quality, two assays employed by different laboratories within the UK's SARS-CoV-2 wastewater monitoring programme were assessed in the Cefas laboratory in Weymouth, UK. The assays were based on Fast Virus (FV) and qScript (qS) chemistries using the same primers and probes, but at different concentrations and under different cycling conditions. Bovine serum albumin and MgSO4 were also added to the FV assay reaction mixture. Two-hundred and eighty-six samples were analysed, and an external control RNA (EC RNA)-based method was used to measure RT-qPCR inhibition. Compared with qS, FV showed a 40.5% reduction in mean inhibition and a 57.0% reduction in inter-sample inhibition variability. A 4.1-fold increase in SARS-CoV-2 quantification was seen for FV relative to qS; partially due (1.5-fold) to differences in reverse transcription efficiency and the use of a dsDNA standard. Analytical variability was reduced by 51.2% using FV while qS increased the number of SARS-CoV-2 negative samples by 2.6-fold. This study indicates the importance of thorough method optimisation for RT-qPCR-based WBE which should be performed using a selection of samples which are representative of the physiochemical properties of wastewater. Furthermore, RT-qPCR inhibition, analytical variability and reverse transcription efficiency should be key considerations during assay optimisation. A standardised framework for the optimisation and validation of WBE procedures should be formed including concessions for emergency response situations that would allow flexibility in the process to address the difficult balance between the urgency of providing data and the availability of resources.


Asunto(s)
COVID-19 , Transcripción Reversa , Humanos , ARN Viral , Aguas Residuales , SARS-CoV-2 , Reacción en Cadena de la Polimerasa
9.
Med Sci Monit ; 29: e938872, 2023 Jan 02.
Artículo en Inglés | MEDLINE | ID: covidwho-2233460

RESUMEN

BACKGROUND This retrospective population study identified 385 191 positive real-time reverse transcription-polymerase chain reaction (RT-PCR) tests for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from a single laboratory in Katowice, Poland, from April 2020 to July 2022. MATERIAL AND METHODS The material was nasopharyngeal, nasopharyngeal swab or bronchial lavage, and bronchoalveolar lavage (BAL) to confirm or exclude SARS-CoV-2 infection with the RT-PCR technique. Personal data are use according to the Provisions on the Protection of Personal Data by the Gyn-Centrum laboratory. RESULTS In 9 months of 2020, the number of SARS-CoV-2 results was 88 986; in 2021, it was 168 439, and in the first 7 months of 2022, it was 12 786. In 2020, the highest number of positive results was recorded in the third quarter (83 094 cases); 2021, in the 1st, 2nd, and 4th quarters (58 712; 37 720; and 71 753 cases, respectively), and in 2022, in the 1st quarter (127 613 cases) of the year. A positive result was observed more often in women and people aged 30-39, followed by those 40-49 years. Patients aged 10-19 years comprised the smallest population of SARS-CoV-2-positive cases. CONCLUSIONS In the Polish population studied, from April 2020 to July 2022, the detection rates of SARS-CoV-2 positivity were significantly higher for women than for men and in the 30-49 age group for both sexes. Also, the infection detection rate of 385 191 out of 1 332 659 patient samples, or 28.9%, supports that the Polish society adhered to public health recommendations for infection control during the COVID-19 pandemic.


Asunto(s)
COVID-19 , SARS-CoV-2 , Masculino , Humanos , Femenino , Adulto , Persona de Mediana Edad , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/epidemiología , Polonia/epidemiología , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Transcripción Reversa , Pandemias , Estudios Retrospectivos , Reacción en Cadena en Tiempo Real de la Polimerasa , Prueba de COVID-19
10.
Influenza Other Respir Viruses ; 17(1): e13084, 2023 01.
Artículo en Inglés | MEDLINE | ID: covidwho-2232390

RESUMEN

BACKGROUND: Measures for mitigation of Coronavirus Disease 2019 (COVID-19) were set to reduce the spread of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). SARS-CoV-2 and other respiratory viruses share similar transmission routes and some common clinical manifestations. Co-circulation of SARS-CoV-2 and other common respiratory viruses is imminent. Therefore, development of multiplex assays for detecting these respiratory viruses is essential for being prepared for future outbreaks of respiratory viruses. METHODS: A panel of three reverse transcription droplet digital PCR (RT-ddPCR) assays were developed to detect 15 different human respiratory viruses. Evaluations of its performance were demonstrated. A total of 100 local and 98 imported COVID-19 cases in Hong Kong were screened for co-infection with other common respiratory viruses. RESULTS: All detected viral targets showed distinct signal clusters using the multiplex RT-ddPCR assays. These assays have a broad range of linearity and good intra-/inter-assay reproducibility for each target. The lower limits of quantification for all targets were ≤46 copies per reaction. Six imported cases of COVID-19 were found to be co-infected with other respiratory viruses, whereas no local case of co-infection was observed. CONCLUSIONS: The multiplex RT-ddPCR assays were demonstrated to be useful for screening of respiratory virus co-infections. The strict preventive measures applied in Hong Kong may be effective in limiting the circulation of other human respiratory viruses. The multiplex assays developed in this study can achieve a robust detection method for clinical and research purposes.


Asunto(s)
COVID-19 , Coinfección , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , Transcripción Reversa , Coinfección/diagnóstico , Coinfección/epidemiología , Reproducibilidad de los Resultados , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos
11.
Adv Healthc Mater ; 12(12): e2202972, 2023 05.
Artículo en Inglés | MEDLINE | ID: covidwho-2219627

RESUMEN

Quantitative polymerase chain reaction (qPCR) is considered the gold standard for pathogen detection. However, improvement is still required, especially regarding the possibilities of decentralization. Apart from other reasons, infectious diseases demand on-site analysis to avoid pathogen spreading and increase treatment efficacy. In this paper, the detection of SARS-CoV-2 is carried out by reverse transcription loop-mediated isothermal amplification, which has the advantage of requiring simple equipment, easily adaptable to decentralized analysis. It is proposed, for the first time, the use of palladium nanoclusters (PdNCs) as indicators of the amplification reaction at end point. The pH of the medium decreases during the reaction and, in turn, a variation in the catalytic activity of PdNCs on the oxygen reduction reaction (ORR) can be electrochemically observed. For the detection, flexible and small-size screen-printed electrodes can be premodified with PdNCs, which together with the use of a simple and small electrochemical equipment would greatly facilitates their integration in field-deployable devices. This would allow a faster detection of SARS-CoV-2 as well as of other future microbial threats after an easy adaptation.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Transcripción Reversa , Paladio , Técnicas de Laboratorio Clínico , Prueba de COVID-19 , Sensibilidad y Especificidad , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , Bioensayo
12.
Int J Infect Dis ; 128: 285-289, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: covidwho-2210481

RESUMEN

OBJECTIVES: During the third wave, the growing number of COVID-19 case clusters reported countrywide in Thailand demonstrated the rapidly evolving characteristics of SARS-CoV-2, the causative agent of the COVID-19 pandemic. The rapid spread of COVID-19 infections had been extensively reported in public areas and construction camps, as well as in congested communities with poor sanitation. High demand for SARS-CoV-2 genome testing and quick reporting by an hour for case identification and isolation characterizes the COVID-19 crisis in Thailand. This situation leads to an urgent need for alternative molecular tests which are reliable, rapid, and cost-effective. METHODS: In this study, we assessed colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP), using real-time reverse transcription-polymerase chain reaction (RT-PCR) as a reference standard, for active case finding in suspected (mostly asymptomatic) cases living in high-risk areas of Bangkok. RESULTS: The diagnostic performance of the RT-LAMP compared with real-time RT-PCR in specimens from 549 Thais were computed in a real-world field study setting. Our study demonstrated that RT-LAMP achieved robust identification of SARS-CoV-2 infection, with a diagnostic sensitivity and specificity of 91.67% and 100%, respectively. CONCLUSION: RT-LAMP is a reliable assay for SARS-CoV-2 detection and is scalable for use in the emergency response to a nationwide pandemic, despite resource limitations. The RT-LAMP real-world data derived from this field study validate its potential use in laboratory practice. RT-LAMP is a good choice as a laboratory-based SARS-CoV-2 molecular test when real-time RT-PCR is not available.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Transcripción Reversa , Pandemias , Colorimetría , Tailandia , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , Sensibilidad y Especificidad , ARN Viral/genética
13.
Microbiol Spectr ; 11(1): e0359122, 2023 02 14.
Artículo en Inglés | MEDLINE | ID: covidwho-2193575

RESUMEN

Multiple mutations in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) increase transmission, disease severity, and immune evasion and facilitate zoonotic or anthropozoonotic infections. Four such mutations, ΔH69/V70, L452R, E484K, and N501Y, occurred in the SARS-CoV-2 spike glycoprotein in combinations that allow the simultaneous detection of VOCs. Here, we present two flexible reverse transcription-quantitative PCR (RT-qPCR) platforms for small- and large-scale screening (also known as variant PCR) to detect these mutations and schemes for adapting the platforms to future mutations. The large-scale RT-qPCR platform was validated by pairwise matching of RT-qPCR results with whole-genome sequencing (WGS) consensus genomes, showing high specificity and sensitivity. Both platforms are valuable examples of complementing WGS to support the rapid detection of VOCs. Our mutational signature approach served as an important intervention measure for the Danish public health system to detect and delay the emergence of new VOCs. IMPORTANCE Denmark weathered the SARS-CoV-2 crisis with relatively low rates of infection and death. Intensive testing strategies with the aim of detecting SARS-CoV-2 in symptomatic and nonsymptomatic individuals were available by establishing a national test system called TestCenter Denmark. This testing regime included the detection of SARS-CoV-2 signature mutations, with referral to the national health system, thereby delaying outbreaks of variants of concern. Our study describes the design of the large-scale RT-qPCR platform established at TestCenter Denmark in conjunction with whole-genome sequencing to report mutations of concern to the national health system. Validation of the large-scale RT-qPCR platform using paired WGS consensus genomes showed high sensitivity and specificity. For smaller laboratories with limited infrastructure, we developed a flexible small-scale RT-qPCR platform to detect three signature mutations in a single run. The RT-qPCR platforms are important tools to support the control of the SARS-CoV-2 endemic in Denmark.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Transcripción Reversa , COVID-19/diagnóstico , Reacción en Cadena de la Polimerasa , Mutación
14.
Microbiol Spectr ; 11(1): e0296622, 2023 02 14.
Artículo en Inglés | MEDLINE | ID: covidwho-2193562

RESUMEN

Coronavirus disease 2019 (COVID-19), which is caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), was initially identified in 2019, after which it spread rapidly throughout the world. With the progression of the epidemic, new variants of SARS-CoV-2 with faster transmission speeds and higher infectivity have constantly emerged. The proportions of people asymptomatically infected or reinfected after vaccination have increased correspondingly, making the prevention and control of COVID-19 extremely difficult. There is therefore an urgent need for rapid, convenient, and inexpensive detection methods. In this paper, we established a nucleic acid visualization assay targeting the SARS-CoV-2 nucleoprotein (N) gene by combining reverse transcription-recombinase polymerase amplification with closed vertical flow visualization strip (RT-RPA-VF). This method had high sensitivity, comparable to that of reverse transcription-quantitative PCR (RT-qPCR), and the concordance between RT-RPA-VF and RT-qPCR methods was 100%. This detection method is highly specific and is not compatible with bat coronavirus HKU4, human coronaviruses 229E, OC43, and HKU1-CoV, Middle East respiratory syndrome coronavirus (MERS-CoV), or other respiratory pathogens. However, multiple SARS-CoV-2 variants are detectable within 25 min at 42°C using this visual method, including RNA transcripts of the Wuhan-Hu-1 strain at levels as low as 1 copy/µL, the Delta strain at 1 copy/µL, and the Omicron strain at 0.77 copies/µL. The RT-RPA-VF method is a simple operation for the rapid diagnosis of COVID-19 that is safe and free from aerosol contamination and could be an affordable and attractive choice for governments seeking to promote their emergency preparedness and better their responses to the continuing COVID-19 epidemic. In addition, this method also has great potential for early monitoring and warning of the epidemic situation at on-site-nursing points. IMPORTANCE The global COVID-19 epidemic, ongoing since the initial outbreak in 2019, has caused panic and huge economic losses worldwide. Due to the continuous emergence of new variants, COVID-19 has been responsible for a higher proportion of asymptomatic patients than the previously identified SARS and MERS, which makes early diagnosis and prevention more difficult. In this manuscript, we describe a rapid, sensitive, and specific detection tool, RT-RPA-VF. This tool provides a new alternative for the detection of SARS-CoV-2 variants in a range as low as 1 to 0.77 copies/µL RNA transcripts. RT-RPA-VF has great potential to ease the pressure of medical diagnosis and the accurate identification of patients with suspected COVID-19 at point-of-care.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , Transcripción Reversa , ARN Viral/genética , Recombinasas/genética , Sensibilidad y Especificidad
15.
PLoS One ; 18(1): e0280243, 2023.
Artículo en Inglés | MEDLINE | ID: covidwho-2197144

RESUMEN

The importance of air purifiers has increased in recent years, especially with the "coronavirus disease 2019" pandemic. The efficacy of air purifiers is usually determined under laboratory conditions before widespread application. The standard procedure for testing depends on virus cultivation and titration on cell culture. This, however, requires several days to deliver results. The aim of this study was to establish a rapid molecular assay which can differentiate between intact infectious and distorted non-infectious virus particles. Feline Coronavirus was selected as model for screening. First the samples were pretreated with enzymes (universal nuclease and RNase cocktail enzyme mixture) or viability dye (propidium monoazide) to eliminate any free nucleic acids. The ribonucleic acid (RNA) from intact virus was released via magnetic beads-based extraction, then the amount of the RNA was determined using real-time reverse transcription polymerase chain reaction (RT-PCR) or reverse transcription recombinase-aided amplification (RT-RAA). All results were compared to the infectivity assay based on the calculation of the 50% tissue culture infectious dose (TCID50). The nuclease has eliminated 100% of the free Feline Coronavirus RNA, while propidium monoazide underperformed (2.3-fold decrease in free RNA). Both RT-RAA and real-time RT-PCR produced similar results to the infectivity assay on cell culture with limit of detection of 102 TCID50/mL. Two UV-C air purifiers with prosperities of 100% inactivation of the viruses were used to validate the established procedure. Both real-time RT-PCR and RT-RAA were able to differentiate between intact virus particles and free RNA. To conclude, this study revealed a promising rapid method to validate the efficacy of air purifiers by combining enzymatic pretreatment and molecular assays.


Asunto(s)
Filtros de Aire , Azidas , Transcripción Reversa , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , ARN , Sensibilidad y Especificidad , Técnicas de Amplificación de Ácido Nucleico/métodos
16.
Viruses ; 15(1)2023 Jan 11.
Artículo en Inglés | MEDLINE | ID: covidwho-2200874

RESUMEN

Multiple lineages of SARS-CoV-2 have been identified featuring distinct sets of genetic changes that confer to the virus higher transmissibility and ability to evade existing immunity. The continuous evolution of SARS-CoV-2 may pose challenges for current treatment options and diagnostic tools. In this study, we have first evaluated the performance of the 14 WHO-recommended real-time reverse transcription (RT)-PCR assays currently in use for the detection of SARS-CoV-2 and found that only one assay has reduced performance against Omicron. We then developed a new duplex real-time RT-PCR assay based on the amplification of two ultra-conserved elements present within the SARS-CoV-2 genome. The new duplex assay successfully detects all of the tested SARS-CoV-2 variants of concern (including Omicron sub-lineages BA.4 and BA.5) from both clinical and wastewater samples with high sensitivity and specificity. The assay also functions as a one-step droplet digital RT-PCR assay. This new assay, in addition to clinical testing, could be adopted in surveillance programs for the routine monitoring of SARS-CoV-2's presence in a population in wastewater samples. Positive results with our assay in conjunction with negative results from an Omicron-specific assay may provide timely indication of the emergence of a novel SARS-CoV-2 variant in a certain community and thereby aid public health interventions.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Transcripción Reversa , Aguas Residuales , COVID-19/diagnóstico , Reacción en Cadena en Tiempo Real de la Polimerasa , Prueba de COVID-19
17.
Clin Lab Med ; 42(2): 237-248, 2022 06.
Artículo en Inglés | MEDLINE | ID: covidwho-2130431

RESUMEN

Reverse transcription-polymerase chain reaction (RT-PCR) tests for severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2), the cause of coronavirus disease 2019 (COVID-19), are approved for qualitative use. The cycle threshold (Ct) value reflects the concentration of viral RNA in the sample, with lower Ct values indicating higher levels of RNA. Caregivers may wish to use the Ct value to determine the progression of infection, how severe the infection will be, and whether the patient can transmit the virus. Variability of Ct values and the data supporting these uses should be considered when deciding whether and how to use Ct values in clinical care.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , ARN Viral/análisis , ARN Viral/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Transcripción Reversa , SARS-CoV-2/genética
18.
Int J Mol Sci ; 23(23)2022 Dec 03.
Artículo en Inglés | MEDLINE | ID: covidwho-2143245

RESUMEN

COVID-19 was officially declared a global pandemic disease on 11 March 2020, with severe implications for healthcare systems, economic activity, and human life worldwide. Fast and sensitive amplification of the severe acute respiratory syndrome virus 2 (SARS-CoV-2) nucleic acids is critical for controlling the spread of this disease. Here, a real-time reverse transcription recombinase-aided amplification (RT-RAA) assay, targeting conserved positions in the nucleocapsid protein gene (N gene) of SARS-CoV-2, was successfully established for SARS-CoV-2. The assay was specific to SARS-CoV-2, and there was no cross-reaction with other important viruses. The sensitivity of the real-time RT-RAA assay was 142 copies per reaction at 95% probability. Furthermore, 100% concordance between the real-time RT-RAA and RT-qPCR assays was achieved after testing 72 clinical specimens. Further linear regression analysis indicated a significant correlation between the real-time RT-RAA and RT-qPCR assays with an R2 value of 0.8149 (p < 0.0001). In addition, the amplicons of the real-time RT-RAA assay could be directly visualized by a portable blue light instrument, making it suitable for the rapid amplification of SARS-CoV-2 in resource-limited settings. Therefore, the real-time RT-RAA method allows the specific, sensitive, simple, rapid, and reliable detection of SARS-CoV-2.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , SARS-CoV-2/metabolismo , Transcripción Reversa , Recombinasas/genética , Recombinasas/metabolismo , COVID-19/diagnóstico , Técnicas de Amplificación de Ácido Nucleico/métodos , Sensibilidad y Especificidad
19.
Anal Bioanal Chem ; 414(23): 6771-6777, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: covidwho-2035027

RESUMEN

The novel coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has infected more than 505 million confirmed cases, including over 6 million deaths. Reference materials (RMs) of SARS-CoV-2 RNA played a crucial role in performance evaluation and quality control of testing laboratories. As the potential primary characterization method of RMs, reverse transcription digital PCR (RT-dPCR) measures the copy number of RNA, but the accuracy of reverse transcription (RT) efficiency has yet to be confirmed. This study established a method of enzymatic digestion followed by isotope dilution mass spectrometry (IDMS), which does not require an RT reaction, to quantify in vitro-transcribed SARS-CoV-2 RNA. RNA was digested to nucleotide monophosphate (NMP) within 15 min and analyzed by IDMS within 5 min. The consistency among the results of four different NMPs demonstrated the reliability of the proposed method. Compared to IDMS, the quantitative result of RT-dPCR turned out to be about 10% lower, possibly attributed to the incompleteness of the reverse transcription process. Therefore, the proposed approach could be valuable and reliable for quantifying RNA molecules and evaluating the RT efficiency of RT-based methods.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Prueba de COVID-19 , Humanos , Isótopos , Espectrometría de Masas , Reacción en Cadena de la Polimerasa , ARN Viral/análisis , ARN Viral/genética , Reproducibilidad de los Resultados , Transcripción Reversa , SARS-CoV-2/genética , Sensibilidad y Especificidad
20.
Arch Pathol Lab Med ; 146(9): 1056-1061, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: covidwho-2025231

RESUMEN

CONTEXT.­: Diagnostic testing for SARS-CoV-2 in symptomatic and asymptomatic children remains integral to care, particularly for supporting return to and attendance in schools. The concordance of SARS-CoV-2 detection in children, using various specimen types, has not been widely studied. OBJECTIVE.­: To compare 3 sample types for SARS-CoV-2 polymerase chain reaction (PCR) testing in children, collected and tested at a single facility. DESIGN.­: We prospectively recruited 142 symptomatic and asymptomatic children/young adults into a sample comparison study performed in a single health care system. Each child provided self-collected saliva, and a trained health care provider collected a mid-turbinate nasal swab and nasopharyngeal (NP) swab. Specimens were assayed within 24 hours of collection by using reverse transcription-polymerase chain reaction (RT-PCR) to detect SARS-CoV-2 on a single testing platform. RESULTS.­: Concurrently collected saliva and mid-turbinate swabs had greater than 95% positive agreement with NP swabs when obtained within 10 days of symptom onset. Positive agreement of saliva and mid-turbinate samples collected from children with symptom onset >10 days prior, or without symptoms, was 82% compared to NP swab samples. Cycle threshold (Ct) values for mid-turbinate nasal samples more closely correlated with Ct values from NP samples than from saliva samples. CONCLUSIONS.­: These findings suggest that all 3 sample types from children are useful for SARS-CoV-2 diagnostic testing by RT-PCR, and that concordance is greatest when the child has had symptoms of COVID-19 within the past 10 days. This study provides scientific justification for using sample types other than the NP swab for SARS-CoV-2 testing in pediatric populations.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Prueba de COVID-19 , Niño , Humanos , Nasofaringe , Pacientes Ambulatorios , Reacción en Cadena de la Polimerasa , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Transcripción Reversa , SARS-CoV-2/genética , Saliva , Manejo de Especímenes/métodos , Cornetes Nasales , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA